TENPOWERINR21700-50XG

Measured at Batemo: the TENPOWER INR21700-50XG delivers 266 Wh/kg energy density and sustains 121 W continuous power in a 21700 cell.

Opened, measured and modelled at Batemo in Karlsruhe, Germany · 196 measured parameters per cell · not datasheet values

Available asModelReportData

Dimensions
21.3 x 70.2mm
Mass
69.1 g
Internal resistance
Insights only — measured at Batemo, available in Batemo Insights
Spread across a measured batch
Insights only — measured at Batemo, available in Batemo Insights
TENPOWER INR21700-50XG: the physical cell next to its Batemo model
The measured cell and its physical model
TENPOWER INR21700-50XG
266 Wh/kg · 2,516 W/kg
04,0008,0000250500power, W/kg →energy, Wh/kg →

this cell342 more sample cells

Show all 17 measured values — and 3 more behind the lock

ENERGY

Gravimetric energy (C/10)
?

The energy exchanged during the C/10 discharge described under Capacity, divided by the cell’s mass or volume. Measured directly, not calculated from the nominal capacity. Full definition

266Wh/kg
Volumetric energy (C/10)
?

The energy exchanged during the C/10 discharge described under Capacity, divided by the cell’s mass or volume. Measured directly, not calculated from the nominal capacity. Full definition

734Wh/L
Absolute energy (C/10)
?

The energy exchanged during the C/10 discharge described under Capacity, in watt-hours. Measured directly, not calculated from the nominal capacity. Full definition

18.38Wh

POWER

Gravimetric power, peak
?

The peak or continuous power above, divided by the cell’s mass or volume. Not a datasheet rating — the current behind it was measured on Batemo’s own test benches. Full definition

2,516W/kg
Gravimetric power, continuous
?

The peak or continuous power above, divided by the cell’s mass or volume. Not a datasheet rating — the current behind it was measured on Batemo’s own test benches. Full definition

1,752W/kg
Volumetric power, peak
?

The peak or continuous power above, divided by the cell’s mass or volume. Not a datasheet rating — the current behind it was measured on Batemo’s own test benches. Full definition

6,948W/L
Volumetric power, continuous
?

The peak or continuous power above, divided by the cell’s mass or volume. Not a datasheet rating — the current behind it was measured on Batemo’s own test benches. Full definition

4,837W/L
Absolute power, peak
?

Peak figures come from the highest current Batemo measured the cell to sustain briefly; continuous figures use the lower current it can sustain without interruption. Both stop at the same 2.5 V / 80 °C condition as the discharge measurements. Full definition

173.9W
Absolute power, continuous
?

Peak figures come from the highest current Batemo measured the cell to sustain briefly; continuous figures use the lower current it can sustain without interruption. Both stop at the same 2.5 V / 80 °C condition as the discharge measurements. Full definition

121.0W

CURRENT

Absolute current, peak
?

The highest constant discharge current Batemo measured the cell to sustain briefly, before the same 2.5 V / 80 °C stop condition applies. Full definition

49.8A
Absolute current, continuous
?

The highest constant discharge current Batemo measured the cell to sustain continuously, before the same 2.5 V / 80 °C stop condition applies. Full definition

35.4A

PHYSICAL

Dimensions
?

Measured on the physical cell at Batemo, in Karlsruhe, Germany — not taken from the manufacturer's drawing. Volume is derived from the measured capacity and its volumetric density, not measured with a caliper. Full definition

21.3 x 70.2mm
Mass
?

Measured on the physical cell at Batemo, in Karlsruhe, Germany — not taken from the manufacturer's drawing. Volume is derived from the measured capacity and its volumetric density, not measured with a caliper. Full definition

69.1g
Volume
?

Measured on the physical cell at Batemo, in Karlsruhe, Germany — not taken from the manufacturer's drawing. Volume is derived from the measured capacity and its volumetric density, not measured with a caliper. Full definition

25.0cm³
Format
?

Measured on the physical cell at Batemo, in Karlsruhe, Germany — not taken from the manufacturer's drawing. Volume is derived from the measured capacity and its volumetric density, not measured with a caliper. Full definition

21700

CELL

Absolute capacity, nominal
?

Discharged from a full charge at a constant C/10 current and 25 °C, until the cell reaches 2.5 V or its surface reaches 80 °C. Nominal is the value from the datasheet; measured, gravimetric and volumetric are what Batemo recorded during that discharge. Full definition

5.00Ah
Absolute capacity, measured (C/10)
?

Discharged from a full charge at a constant C/10 current and 25 °C, until the cell reaches 2.5 V or its surface reaches 80 °C. Nominal is the value from the datasheet; measured, gravimetric and volumetric are what Batemo recorded during that discharge. Full definition

5.12Ah
Mean voltage (C/10)
?

The charge-averaged voltage across the same C/10 discharge — the exchanged energy divided by the exchanged charge, not a single number picked from a curve. It is a measured mean, not the nominal voltage printed on a datasheet. Full definition

3.59V

In Batemo Insights

Impedance spectrum (EIS)
Insights only — measured at Batemo, available in Batemo Insights
Heat generation and thermal properties
Insights only — measured at Batemo, available in Batemo Insights
Capacity loss after formation
Insights only — measured at Batemo, available in Batemo Insights

What this cell does when you actually load it.

The table above gives you one capacity number. Below is what TENPOWER INR21700-50XG does under load — measured on our own test bench, across many operating points and several ambient temperatures. Every cell in the library is measured under identical conditions, which is what makes them comparable at all. At 1C — the one rate measured on every cell — usable energy is 87% to 99% of what the same cell delivers at C/10.

All three panels below use the same 15 measured operating points, at 25 °C ambient.

energy

15 pts · 25 °C · lin

How much energy can it deliver?

The graph visualizes how much energy the cell can deliver when operated at different powers.

usable energy / Wh

5.010.015.020.00100200300

discharge power / W

At 25 °C ambient, TENPOWER INR21700-50XG delivers 5.5 Wh at 314 W — down from 18.4 Wh at C/10 (1.8 W).

thermal

15 pts · 25 °C · lin

How hot does it get?

The greater the thermal losses, the more the cell heats up, resulting in higher depleted power.

max. surface temperature / °C

204060800100200300

discharge power / W

At 25 °C ambient, TENPOWER INR21700-50XG's surface reaches 64.4 °C at 314 W — up from 26.2 °C at C/10 (1.8 W).

runtime

15 pts · 25 °C · log

How long can it deliver the power?

The more power the cell supplies, the shorter it can deliver the power.

runtime to cutoff / s (log)

10100100010k100k0100200300

discharge power / W

At 25 °C ambient, TENPOWER INR21700-50XG runs for 1 min at 314 W — down from 10 h 14 min at C/10 (1.8 W).

The top 3 challenges you face with this cell.

Every cell is a compromise. This cell's own measurements point to three challenges you will face with it. Each one shows the number behind it and where Batemo helps you solve it.

Cell selection

Choosing the right cell

18.38Wh121W

and that is all a datasheet will tell you

Energy

third quarter of 343 cells

Continuous power

third quarter of 343 cells

the challenge

The datasheet says 5.00 Ah. But how much does it deliver in your system?

Looking at energy and power alone is not enough. Your duty cycle is neither C/10 nor 1 C, and somewhere in between the ranking between two cells can invert.

Cell selection

Thermal analysis

Getting the heat out

about 112mW/cm²

of heat at typical operation — 6.1 W in total

heat out

54 cm² of surface

the challenge

I am asking this cell for 35.4 A all day, out of 69.1 g. Where does that heat go?

A surface temperature is not the temperature that decides. What no sensor on a finished cell can show is the temperature inside it — and the gap between the two grows exactly where it matters.

Thermal analysis

Lifetime

Making it last

5.12Ah

measured at C/10 — the schematic curves above all start here

cycles →

the challenge

This capacity describes the cell at the beginning of its life. How does it change under different operating conditions?

A cycle test tells you what happened under that one test. It does not tell you which mechanism took the capacity away, and it does not tell you what to change.

Lifetime

These three are the challenges this cell's own numbers raise. Which of them decides your product is something only your load profile can say — and that is the next question, not this one.

What the model of the TENPOWER INR21700-50XG answers that the measurement cannot.

Batemo built a physics-based model of the TENPOWER INR21700-50XG from the measurements above, then checked it against the full set of validation experiments — discharge, charge, pulses and profiles. Across all of them the model deviates from the measurement by 0.020 V in voltage and 0.9 K in surface temperature, in root mean square. These are deviations Batemo measured, not a tolerance Batemo promises.

“If you can show us another battery cell model that is more accurate, we will refund your money.”

BatemoOn every one of the 198 Batemo Cell Models in the library
Voltage
0.020V
0.6 % of the measured range
Temperature
0.9K
0.9 % of the measured range
Power
0.80W
0.6 % of the measured range
Energy
0.160Wh
1.5 % of the measured range

More on the Batemo Cell Model ›

Each value is the root mean square of the difference between measurement and simulation, across the full set of validation experiments for this cell — discharge, charge, pulses and profiles. A quarter of those experiments is known only to the party challenging the model, and not to Batemo. Model reference B0487.

How this cell sits in the field.

Nearest by measured specific energy and power — the two axes of the Ragone map above. Not by chemistry, and not a recommendation. Other numbers, like continuous current, can still differ a lot.

The two closest cells in the library

Also close · 4.6% apart

Ampace JP50P1(C)

21700
  • Gravimetric energy260 Wh/kg-2.1%
  • Gravimetric power, peak2,420 W/kg-3.8%
  • Absolute current, continuous31.7 A-10.6%
  • Mass70 g+1.4%
Open cell page
This cell at the center of a map of specific energy (horizontal) and specific peak power (vertical). Same build + closest behaviour: Reliance INR21700-RS50, 3.4% apart. Also close: Ampace JP50P1(C), 4.6% apart.×1.10×0.91×1.10×0.91energy →power ↑2%5%

Ring percentages measure overall distance — energy and power combined. The ×-numbers on the dashed box measure just one axis: a point on that edge has that many times this cell's own specific energy or power.

  • This cell
  • Other cells, same build, in window

Same build + closest behaviour · 3.4% apart

Reliance INR21700-RS50

21700
  • Gravimetric energy274 Wh/kg+3.1%
  • Gravimetric power, peak2,552 W/kg+1.4%
  • Absolute current, continuous32.4 A-8.6%
  • Mass66 g-4.5%
Open cell page
What nextCompare cells